Workstation vertical
System details
- Automatic vertical front sash (clear)
- Light curtain for activity monitoring
- Integrated LED lights
- Monitoring of differential pressure and filter loading
- Temperature monitoring of exhaust air
- Programmable logic controller (PLC) for monitoring and controlling of operation, airflows, and equipment
- Supply air filters according to ISO class
- Volume flow controllers for supply and exhaust air
- Connections for hotplates
- Bottling station (various versions)
- Exhaust tub flushing
- Drain / wastewater connection
- Customized media supply (interior and exterior)
- Remote monitoring and servicing
- Integrated ultrapure water system (various manufacturers)
- Integrated acid stills
- Sink or ultrasonic basin
- Base cabinet (vented) with hinged doors or drawers
- Exhaust air scrubber and exhaust air irrigation

Laminar flow
DIN EN 14175
Modular design
Reduce energy consumption
MK Workstation vertical
Our metal-free systems are characterized by their modular design, enabling us to create custom-made solutions tailored to your specific needs:
Top Module: Regulated ventilation system with filtered laminar airflow
Middle Module: Customizable work surface and front sliding panel
Base Module: Flexible substructure for additional storage space or legroom
The metal-free construction allows for contamination-free sample preparation at the highest level, for example, in trace analysis applications.
Product features
- Metal-free construction (no exposed metal) to prevent contamination and corrosion
- Supply air provided directly from ventilation system (via dedicated duct) or, alternatively, pulled from room (using support fan)
- Vertical laminar flow achieved though a fine-meshed monofilament fabric diffuser
- Laminar airflow throughout the entire working chamber; air is exhausted through perforated work surface
- Control of supply air and exhaust air via the PLC ensures the correct pressure in the working chamber
- Compliant with DIN EN 14175-3 safety and performance standards (containment, air exchange efficiency)
- Simultaneous protection of personnel and samples/products
- Outstanding air and energy efficiency due to optimized and smart airflow management
- Exhaust air can be discharged via air scrubbers or directly transferred to the exhaust air system
- Room air can also be extracted via the base module and fed into the ventilation system (‘recirculating air’)
| Technical data | ||
| Materials | PP, PET, POM, PFA, PVDF | |
| Operating voltage | 400 V, 5-pin | |
| Air volume requirements | Supply air min. 400 m³/h, exhaust air min. 450 m³/h (Width: 1200 mm) | |
| Air velocity in working area |
ca. 0.15 m/s |
|
| Terminal supply air filters |
High-performance HEPA fi lter, fi lter class H13 to U16 (depending on requirements) with pre-filter F9 |
|
| Cleanroom classes according DIN EN ISO 14644-1 |
Class 3 or better (0.2 μm, 0.3 μm) „at rest“ |
|
| Compliance with the DIN EN ISO 14175 |
Defined safety specifications of the retention and air exchange capacity for personal and product protection |
|
| Illuminance |
> 750 Lux |
|
| Interfaces |
Ethernet or other common fieldbus systems and serial interfaces |
|
| Dimensions |
1200 x 975 x 2260 mm (W x D x H), Widths 900 mm, 1500 mm and 1800 mm also available |
|
| Weight (without equipment) |
260 kg for 1200 mm width (320 kg, 380 kg for higher widths) |
|
| Dimensions working area |
1180 x 690 x 880 mm (W x D x H), width varies with total width |
|
| Working height |
700 mm, 900 mm |
|
| Front sash opening height |
Individually adjustable via PLC |
|